No heat | 1. | Power is off. |
|
|
| Check the circuit | |
| 2. | Set | temperature | is | in | Adjust the set value | |
|
| improper position |
|
|
| ||
| 3. | Connector has fallen off. | Tighten the plug. | ||||
| 4. | Heater is defective |
| Change the heater. | |||
| 5. | Fuse is open. |
|
|
| Change the fuse. | |
| 6. | Control panel |
| is | not | Change the circuit panel. | |
|
| working. |
|
|
|
| |
The fan doesn’t operate | 1. | Control panel is faulty. |
| Change the panel. | |||
| 2. | The | capacitor |
| of | fan | Change the capacitor. |
|
| defective. |
|
|
|
| |
| 3. | Fan defective. |
|
|
| Change the fan. | |
Unusual sound or heavy | 1. | Installation | of | the | Check Installation. | ||
shaking |
|
|
| too |
| ||
|
| gradient. |
|
|
|
| |
| 2. | Fan touches with other |
| Adjust the fan position. | |||
| hardware. |
|
|
|
| ||
| 3. | The | connective |
| pipelines | Adjust the position between | |
|
| collide with each other. |
| the pipelines. | |||
| 4. | The part becomes flexible. | Tighten screws. |
Installation
1.Installation preparation
If you need to install the
The gradient of install the platform must no more than 5°. If greater than 5° it can be influenced that condensation water of the air conditioner could overflow.
You must avoid any wire and any pipeline before incision.
2.Please directly install the top of the
7