Cautions

1.In any case the compressor will restart 3 minutes after power failure

2.The air-conditioner adopts three core plugs: Modification will void warranty

3.Working voltage of the air-conditioner must keep within the range of 115VAC±10. If the voltage is too high or low will lead to damage of the compressor.

4.The normal working environment temperature of the air conditioner is: 0F to115F

Maintenance and Safeguard

It will keep at maximum performance ratings if you perform routine maintenance. After running for 90 days, you must clean up dust around the fins of the heat exchanger in order to keep refrigeration performance at optimum

TROUBLE SHOOT CHART

Problem

Possible Cause

 

 

 

 

Solution

Doesn’t cool / heat

1.

The voltage of the power

Adjust the voltage range into

 

 

is lower than 97V

 

 

normal demand.

 

2.

You

are

using

an

Do not use an extension cord.

 

 

extension cord for the unit

 

 

3.

The system leaks Fluorine

Call repair technician

 

4.

Button “ON/OFF” failure

Replace button “ON/OFF”.

 

5.

Set the temperature to the

Refer to operation explanation.

 

 

abnormal position.

 

 

 

 

6.

Compressor not working.

Turn off for ten minutes. Turn

 

 

 

 

 

 

 

 

back on

 

7.

The

sub

cooling

of

Call repair technician

 

 

compressor

is

protected

 

 

 

and does not work

 

 

 

 

8.

Capillary is blocked

 

Call repair technician

 

 

 

 

 

 

 

Inadequate cooling

1.

The

evaporator

 

and/or

Clean the evaporator and

 

 

condenser are blocked by

condenser.

 

 

debis .

 

 

 

 

 

 

2.

The

doors

and

windows

Reduce times that open the

 

 

have opened frequently.

 

door.

 

3.

Heat load is too high.

 

Installation of larger unit.

 

4.

Set

temperature

is

in

Adjust the set value.

 

 

improper position.

 

 

 

 

5.

Capillary is blocked.

 

Call repair technician

 

6.

The

refrigeration

system

Call repair technician

 

 

has failed.

 

 

 

 

 

 

 

 

6

 

 

 

 

 

Page 7
Image 7
Soleus Air air-condition Cautions, Maintenance and Safeguard, Trouble Shoot Chart, evaporator, and/or, debis, temperature