Optional Wall Thermostat or Remote Control
Use only a 750 millivolt DC
The thermostat should be connected to the Nordic QT using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly above the ignitor button. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Fig. 23.
For thermostatic operation, the
At the thermostat, the two wires should be con- nected to the two connection screws on the thermostat base plate per the manufacturer’s instructions.
Remote Control
When using a remote, the remote receiver should be wired to the terminal block the same way the thermo- stat would be. See the instructions above.
Follow the operating instructions included with the Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER OR DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERA- TION AFTER SERVICING THE APPLIANCE.
Log Set Installation
The Nordic QT is equipped with a one piece log set and is packaged in bubble wrap inside the firebox. The log set must be removed from the packaging and arranged in the unit prior to start up of the gas stove. Do not handle the log set with your bare hands. Always wear gloves to prevent skin irritation from the ceramic fibers.
To install the log set, remove the packaging and place the log set inside the firebox, centered and pushed completely back against the rear wall of the stove.
See fig. 24.
Also included is a bag of ember stones that will simulate glowing embers when the burner is operating. These should be broken into
NOTE: All the embers do not have to be used.
THE CERAMIC FIBER LOGS AND GLOWING EMBERS CAN IRRITATE YOUR SKIN. GENTLY WASH YOUR HANDS WITH WARM SOAPY WATER AFTER HANDLING THE LOGS.
Pilot Assembly
Place EmberLocation stones on screen
Figure 24. Center the Log Set within the firebox.
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
Figure 23. Accessory wiring diagram.
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
18