Jotul GF100 DV GF 100 DV Nordic QT Specifications, Hardware Bag Contents, Input Rates, Propane

Models: GF100 DV

1 28
Download 28 pages 56.27 Kb
Page 4
Image 4
GF 100 DV Nordic QT

GF 100 DV Nordic QT

Specifications

Input Rates

Natural Gas

14,500 BTU/hr. maximum input

10,600 BTU/hr. minimum input

Propane

14,000 BTU/hr. maximum input

10,900 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

11.0 WC (2.74 kPa)

13.0 WC (3.23 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas:

2.2 WC (.55 kPa)

3.5 WC (.85 kPa)

Propane:

6.5 WC (1.59 kPa)

10.0 WC (2.49 kPa)

Piezo Ignitor / Standing Pilot

Weight: 150 lbs.

Suggested Tools for

Installation and Service

External regulator (for Propane only)

Piping which complies with local code

Manual shutoff valve (T-Handle in Massachusetts)

Sediment trap - if required by code

Tee joint

Pipe wrench

Pipe sealant

10 mm open end wrench

1/2”, 7/16” open end wrench or deep socket

Phillips head screwdriver

Flat head screwdriver

1/4” nut driver

4 mm allen wrench

Gloves

Safety glasses

Torx T20 screwdriver

Leak test solution

Reciprocating Saw

Power Drill

22 1/4”

21”

15 1/4”

21”

Flue Collar

Centerline

16 1/2”

21”

Hardware Bag Contents

 

Fuel Conversion Kit - LP

154379

Exhaust Restrictor Plate

12934492

Wall Shield

12948792

Ember Bag , 6 oz

129123