GF 100 DV Nordic QT
Specifications
Input Rates
Natural Gas
14,500 BTU/hr. maximum input
10,600 BTU/hr. minimum input
Propane
14,000 BTU/hr. maximum input
10,900 BTU/hr. minimum input
Inlet Pressure: | MIN | MAX | |
Natural Gas: | 5.0 WC (1.24 kPa) | 7.0 WC (1.74 kPa) | |
Propane: | 11.0 WC (2.74 kPa) | 13.0 WC (3.23 kPa) | |
Manifold Pressure: | MIN | MAX | |
Natural Gas: | 2.2 WC (.55 kPa) | 3.5 WC (.85 kPa) | |
Propane: | 6.5 WC (1.59 kPa) | 10.0 WC (2.49 kPa) |
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
Suggested Tools for
Installation and Service
•External regulator (for Propane only)
•Piping which complies with local code
•Manual shutoff valve
•Sediment trap - if required by code
•Tee joint
•Pipe wrench
•Pipe sealant
•10 mm open end wrench
•1/2”, 7/16” open end wrench or deep socket
•Phillips head screwdriver
•Flat head screwdriver
•1/4” nut driver
•4 mm allen wrench
•Gloves
•Safety glasses
•Torx T20 screwdriver
•Leak test solution
•Reciprocating Saw
•Power Drill
22 1/4”
21”
15 1/4”
21”
Flue Collar
Centerline
16 1/2”
21”
Hardware Bag Contents |
| |
• | Fuel Conversion Kit - LP | 154379 |
• | Exhaust Restrictor Plate | 12934492 |
• | Wall Shield | 12948792 |
• | Ember Bag , 6 oz | 129123 |