Jotul GF100 DV manual Stove and Vent Clearance Requirements, Alcove Installation, Horizontal Run

Models: GF100 DV

1 28
Download 28 pages 56.27 Kb
Page 7
Image 7
Stove and Vent Clearance Requirements
0” (0 mm) 25” (635 mm) 2” (50 mm) 3” (76 mm)
10” (254 mm) - for access to Lighting Instruction plate

Stove and Vent Clearance Requirements

Minimum Clearances from the Stove to Combustibles: See figs. 2-4.

Rear:

Ceiling:

Corner:

Right Side:

Left Side:

Minimum Clearances from the Vent Pipe to Combus- tibles:

Horizontal Run:

 

 

 

 

Off the top of the pipe

2”

(50 mm)

Off the sides and bottom

1”

(25 mm)

Vertical Run:

 

 

 

 

All sides

1”

(25 mm)

 

CLEARANCE TO REAR WALL IS= (0”) ZERO CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10” *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(250 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(80 mm)

 

Left Side

Right Side

*Allow 10” on left side of the appliance for complete access to the lighting instructions and control valve.

Figure 3. Parallel Installation Clearances.

24”or greater

Mantel Depth or Ceiling

12” or less

6” or less

25”

 

4”or less

635 mm

16”

 

 

 

 

406 mm

 

 

9”

 

 

229

6”

 

mm

 

152 mm

1” deep trim must be 4” (102 mm) off the top of the stove.

2”

50 mm

2”

50 mm

Figure 4. Corner Clearances.

Alcove Installation

Maximum Alcove Depth: 24” (610 mm)

Minimum Alcove Width: 34” (864 mm)

Minimum Ceiling Height: 47” (1094 mm)

Figure 2. Mantel and Trim Clearance specifications.

7

Page 7
Image 7
Jotul GF100 DV Stove and Vent Clearance Requirements, Alcove Installation, Horizontal Run, Vertical Run, Corner Clearances