Operation Tips

Operation and Performance

*Heating Performance

This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating perfomance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.

Instructions relating to heating (*) are applicable only to "HEAT & COOL TYPE".

Temperature and Humidity Range

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low outdoor air temperature high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Automatic Defrosting function. If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 12 minutes).

During Automatic Defrosting operation, the OPERATION Indicator Lamp will flash.

*Trouble alarming performance

During operation, when there is any trouble,

the operation indicator lamp will flash with different times.

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

10

 

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

14.5

--

--

 

 

 

outdoor

DB C

7

24

-7

 

WB C

6

18

--

 

 

If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Do not use this unit for any other purposes except for the Cooling, Heating, Dehumidifying, and air- circulation of rooms in ordinary dwellings.

The wiring method should be in line with the local wiring standand.

The waste battery should be disposed properly.

If the fuse on PC board is broken, please change it with the type T 3.15A/250VAC. The indoor unit installation height is at least 2.5m.

10

Page 12
Image 12
Haier HCFU-42HF03, HCFU-42CF03 installation manual Operation Tips, Operation and Performance Heating Performance

HCFU-42CF03, HCFU-42HF03 specifications

The Haier HCFU-42HF03 and HCFU-42CF03 are advanced air conditioning units that highlight Haier's commitment to innovation and efficiency in climate control technology. Designed for both residential and light commercial applications, these models stand out for their powerful performance, energy efficiency, and user-friendly features.

One of the main features of the HCFU-42HF03 and HCFU-42CF03 is their dual-function capability, providing both heating and cooling. This versatility makes them a year-round solution for maintaining indoor comfort, regardless of the external weather conditions. Utilizing cutting-edge inverter technology, these units adjust the compressor speed based on the cooling or heating demand, ensuring optimal temperature regulation with reduced energy consumption.

Both models boast impressive energy efficiency ratios (EER) and seasonal energy efficiency ratios (SEER), aligning with global standards for eco-friendly operations. The units are designed to minimize energy wastage, allowing users to enjoy a comfortable environment while keeping electricity bills manageable. Their advanced refrigerant management systems enhance performance further, allowing for rapid cooling and heating responses.

In terms of features, the HCFU-42HF03 and HCFU-42CF03 come equipped with a robust air filtration system. This system effectively captures dust, allergens, and other particulates, improving indoor air quality, which is especially beneficial for allergy sufferers. The models also include programmable timers and remote control functionality, allowing users to customize their cooling or heating schedules for maximum convenience.

Another critical characteristic is their whisper-quiet operation. The advanced engineering of these units minimizes noise levels significantly, ensuring they can be used in noise-sensitive environments, such as bedrooms or offices, without disturbance.

In addition, both the HCFU-42HF03 and HCFU-42CF03 are designed with durability in mind. The rugged build quality ensures reliable operation over the years, while the contemporary aesthetic allows them to blend seamlessly with various interior designs.

Overall, the Haier HCFU-42HF03 and HCFU-42CF03 represent the pinnacle of modern air conditioning technology. Their combination of versatile functionality, impressive efficiency, user-friendly features, and commitment to air quality makes them an excellent choice for anyone looking to enhance their indoor climate control system.