CONNECTION PIPE REQUIREMENT
Side cover A (Right side) Side cover A (Left side)

INSTALLATION PROCEDURE Installation of Indoor Unit

CONNECTION PIPE REQUIREMENT

Table 1

M o d e l

Diameter

Maximum

Maximum height

 

 

(between indoor

 

Liquid side

Gas side

length

and outdoor)

HCFU-42CF03 HCFU-42HF03

9.52 mm

19.05mm

50 m

30 m

 

 

 

 

 

 

INSTALLATION PROCEDURE

Install the room air conditioner as follows:

1. REMOVE THE INTAKE GRILL AND SIDE COVER

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Air filter

(1) Remove the Air filters

(2) Remove the intake grilles

(3) Remove the Side cover A (Right and left side)

(4)This air conditioner can be set up to intake fresh air . For information about how to install for

fresh-air intake, refer to page 23 "FRESH-AIR INTAKE".

2.LOCATION OF CEILING SUSPENSION BOLTS

Manual background Intake grille

Fig. 3

30mm

Suspension bolt pitch 1530mm

INDOOR UNIT (TOP VIEW)

30mm

Dimensions

(Space Required for installation)

10mm

155mm

300mm

Suspension bolt should extend outward 30 to 50mm.

For half-concealed installation

Supension-bolt pitch should be as shown in Fig.4.

Fig. 4

40mm

Ceiling Opening:1530mm

40mm

 

 

 

 

 

 

 

Manual backgroundManual backgroundCeiling panel

Ceiling Opening:640mm

Suspension bolt should

15mm

 

extend outward 30 to 50mm.