Haier HCFU-42HF03 Installation of Indoor Unit, Electrical Wiring, B.For strand wiring

Models: HCFU-42CF03 HCFU-42HF03

1 29
Download 29 pages 33.15 Kb
Page 22
Image 22
ELECTRICAL WIRING

B.For strand wiring Installation of Indoor Unit

ELECTRICAL WIRING

HOW TO CONNECT WIRING TO THE TERMINALS A.For solid core wiring (or F-cable)

(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm) of expose the solid wire.

(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board. (3)Using pliers,bend the solid wire to form a loop suitable for the terminal screw.

B.For strand wiring

(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 3/8"(10mm) of expose the solid wire.

(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.

Fig. 14

Strip 15/16"(25mm)

A. Solid wire

 

B. Strand wire

 

Loop

15/16"(25mm)

 

 

Insulation

 

Strip

 

 

Round terminal

 

Screw with

 

special washer

 

Round

 

terminal

 

Terminal

Wire

board

 

 

Wire

Screw with special washer

Round terminal

HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP

After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.15

20

Page 22
Image 22
Haier HCFU-42HF03 Installation of Indoor Unit, Electrical Wiring, B.For strand wiring, A. Solid wire, B. Strand wire