 Installation procedures Electric wiring
terminal block
table clamp
HPU-42HI03HPU-48HK03

Manual backgroundManual background Installation procedures Electric wiring

Note:

Manual background Electric wiring must be done by qualified person.

Manual background Use copper wire only, the parameter of connecting cable is H07RN-F 4G 0.75mm2.

Manual background The power cable should be over 5G2.5mm2, the power cable and connecting cable are self-provided.

Manual background The power supply connects from the outdoor unit. Wiring of indoor unit

Manual background Insert the cable from outside the wall hole where piping already exist.

Manual background Pull it out from front.

Manual background Loosen terminal screws and insert cable end fully into terminal block, then tighten it. Manual background Pull the cable gently to make sure it is tight.

Manual background Replace cover after wiring. Wiring of outdoor unit

OKNO

Manual background Insert the cable from inside the wall hole where piping already exists.

Manual background Pull it out from front.

Manual background Loose terminal screw and insert cable end fully into terminal block, then tighten it.

Manual background Pull the cable gently to make sure it is tight. Manual background Replace cover after wiring.

HPU-42CH03 HPU-48CJ03 HPU-48HJ03 HPU-42HH03

Y/G

INDOOR UNIT TERMINAL BLOCK

1

2

3

 

 

Y/G

R S T N 1 2 3

OUTDOOR UNIT

 

 

TERMINAL BLOCK

POWER SUPPLY

Note:

Manual background When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks.Incorrect wiring may damage air conditioner's controller or cause operation failure.