Haier HSU-0912RF03 Power Source, Selection of pipe, Selection of Installation Place Outdoor Unit

Models: 001051 HSU-0912RF03

1 12
Download 12 pages 31.91 Kb
Page 2
Image 2
Selection of Installation Place Outdoor Unit

Power Source 140

415

280

140 Selection of pipe

Floor fixing dimensions of the outdoor unit (Unit:mm)

Fixing of outdoor unit

Fix the unit to concrete or block with bolts(Manual background10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Indoor Unit

Selection of Installation Place Outdoor Unit

Manual background Place, robust not causing vibration, where the body can be supported sufficiently.

Manual background Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.

Manual background Place, possible to drain easily, where piping can be connected with the outdoor unit.

Manual background Place, where cold air can be spread in a room entirely.

Manual background Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Manual background Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.

Manual background In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Manual background Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Manual background Place, possible to bear the unit, where vibration and noise are not increased.

Manual background Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Manual background Place, where a distance marked Manual backgroundis available as illustrated in the above figure.

Power Source

Manual backgroundBefore inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Manual backgroundInstall an exclusive branch circuit of the power.

Manual backgroundA receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

Selection of pipe

To this unit, both liquid and gas pipes shall be insulated

 

 

as they become low temperature in operation.

 

 

Use optional parts for piping set or pipes covered with

 

 

Liquid pipe

6.35mm(1/4")

equivalent insulation material.

 

 

The thickness of the pipe must be 0.8mm at least.

Gas pipe

9.52mm(3/8")

 

 

 

 