Haier HSU-07HEK03, HSU-09LEK13, HSU-09LEK03, HSU-07LEK03, HSU-09HEK03 Selection of pipe, Indoor unit

Models: HSU-12LEK13 HSU-12HEK03 HSU-12LEK03 HSU-09HEK03 HSU-07LEK03 HSU-07HEK03 HSU-09LEK03 HSU-09LEK13

1 4
Download 4 pages 48.72 Kb
Page 2
Image 2
Selection of pipe

 

 

 

280

 

 

256

 

 

5

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

3

 

140

415

140

140

500

140

113.5

583

113.5

 

 

 

 

 

 

 

 

Floor fixing dimensions

Floor fixing dimensions

Floor fixing dimensions

 

of the outdoor unit

of the outdoor unit

 

 

of the outdoor unit

(Unit:mm)

 

 

 

(Unit:mm)

 

 

 

 

(Unit:mm)

 

 

HSU-24LEK13

 

 

 

 

 

 

 

 

 

 

 

HSU-09LEK13

HSU-09LEK03

HSU-09LEK03/(DB)

 

 

HSU-18LEK03/(DB)

 

 

 

 

 

 

 

HSU-12LEK13

HSU-12LEK03

HSU-12LEK03/(DB)

 

 

 

 

 

HSU-07LEK03

HSU-09HEK03

HSU-18LEK13

 

 

 

 

 

HSU-108CH09

 

 

 

 

 

HSU-07HEK03

HSU-12HEK03

 

 

 

 

 

HSU-138CH09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HSU-12LEK13-M

 

 

 

 

 

 

 

 

 

HSU-18HEK03

 

 

 

 

 

 

 

 

 

 

 

 

HSU-24HEK03

 

 

Selection of pipe

Indoor unit To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation.

Manual background Use optional parts for piping set or pipes covered with equivalent insulation material.

 

 

For 07 09 108

For 12 18 138

For 24

 

 

 

 

 

Liquid pipe (

)

6.35mm(1/4")

6.35mm(1/4")

9.52mm(3/8")

 

 

 

 

 

Gas pipe (

)

9.52mm(3/8")

12.7mm(1/2")

15.88mm(5/8")

 

 

 

 

 

Indoor unit

1.Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is first fixed

1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.

2.Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.

3.Find the wall hole location A using a measuring tape

B= Manual background60mm

B= 60mm

HSU-24HEK03

 

 

HSU-24LEK13

A=145mm

30mm

HSU-12LEK13-M HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-07HEK03 HSU-09LEK03/(DB) HSU-12LEK03/(DB)

HSU-09LEK03

A=145mm

30mm

 

 

 

HSU-12LEK03

 

 

HSU-09HEK03

 

 

HSU-12HEK03

 

 

HSU-108CH09

 

 

HSU-138CH09

 

 

Manual backgroundManual backgroundManual backgroundManual backgroundHSU-18HEK03 Manual backgroundManual background HSU-18LEK13

HSU-18LEK03/(DB)

B=

60mm

A=145mm

30mm

 

2.Making a Hole on the Wall and Fitting the Piping Hole Cover

Manual background Make a hole of 60 mm in diameter, slightly descending to outside the wall. Manual background Install piping hole cover and seal it off with putty after installation

Indoor side

Outdoor side

Wall hole

Thickness

60mm

of wall

 

(Section of wall hole)

G Piping hole pipe

2

Page 2
Image 2
Haier HSU-07HEK03, HSU-09LEK13, HSU-09LEK03, HSU-07LEK03, HSU-09HEK03, HSU-12LEK03, HSU-12HEK03 Selection of pipe, Indoor unit