Haier HSU-07LEK03, HSU-09LEK13 Indoor unit, Connecting the indoor/outdoor Electric Cable

Models: HSU-12LEK13 HSU-12HEK03 HSU-12LEK03 HSU-09HEK03 HSU-07LEK03 HSU-07HEK03 HSU-09LEK03 HSU-09LEK13

1 4
Download 4 pages 48.72 Kb
Page 3
Image 3
Indoor unit
Power cable: 3G1.0mm

Indoor unit

Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Connecting the indoor/outdoor Electric Cable Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.

When connecting the cable after installing the indoor unit

1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed.

2. Pull out the cable on the front side, and connect the cable making a loop.

When connecting the cable before installing the indoor unit

Manual background Insert the cable from the back side of the unit, then pull it out on the front side.

Manual background Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.

Manual background Pull the cable slightly to make sure the cables have been properly inserted and tightened.

Manual background After the cable connection, never fail to fasten the connected cable with the wiring cover.

Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect.

1.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).

2.If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.

If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.

3.The wiring method should be in line with the local wiring standard.

4.After installation, the power plug should be easily reached.

5.A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the

distance between its two contacts should be not less than 3mm.

Indoor unit

HSU-09LEK03/(DB) HSU-12LEK03/(DB)

1(N)

2(L)

3(C)

Outdoor unit

HSU-108CH09

HSU-138CH09

3 4

Power cable:

 

3G1.0mm

 

3G1.0mm

Indoor unit

Outdoor unit

HSU-12LEK13-M

3 4

Power cable:

 

5G1.0mm

 

Indoor unit

HSU-12HE K03

Outdoor unit

 

HSU-07HE K03

 

 

 

HSU-09HE K03

 

 

HSU-18HEK03

 

5

 

 

connecting wiring:

Manual background 3G1.5mmManual background +1X0.75mm Manual background Power cable: Manual background 3G1.0mmManual background

3G1.5mm

3G2.0mm

Indoor unit HSU-18LEK13Outdoor unit

4

Power cable:

 

3

3G2.5mm

 

2

4G0.75mm

1

 

Indoor unit

HSU-24LEK13

Power cable:

 

3G1.5mm

 

4G0.75mm2

 

Indoor unit

{

POWER

HSU-18LEK03/(DB)

Outdoor unit

5

4

3

2

1

Indoor unit

Power cable:

 

3G2.5mm

 

6G0.75mm

 

HSU-24HEK03

Outdoor unit

 

 

BR

L

POWER

BL

N

 

 

SUPPLY

Y/G

 

 

 

 

Outdoor unit

 

1(L) 2(N)

Indoor unit

Outdoor unit

HSU-09LEK13 HSU-09LEK03 HSU-12LEK13 HSU-12LEK03 HSU-07LEK03

connecting wiring:

-mod 07-12:Manual background 3G1.0mmManual background Power cable:

-mod 07-12: Manual background 3G1.0mmManual background