Haier HSU-1218CR03 Outdoor unit, Installation of Outdoor Unit, Connection of pipes, Half union

Models: HSU-1218CR03

1 8
Download 8 pages 20.78 Kb
Page 6
Image 6
Outdoor unit

Outdoor unit

1.Installation of Outdoor Unit

Install according to Drawing for the installation of indoor and outdoor units

2.Connection of pipes

1.Installation of Outdoor Unit To bend a pipe, give the roundness as large as possible not to crush the pipe 2.Connection of pipes Connecting the pipe of gas side first makes working easier.

Half union

 

 

Flare nut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spanner

Torque wrench

Forced fastening without careful centering may damage the threads and cause a leakage of gas.

Pipe Diameter ( )

Fastening torque

 

 

 

Liquid side 6.35mm(1/4")

18N.m

 

 

Gas side 12.7mm(1/2")

55N.m

 

 

 

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.

3.Connection

Half union Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws.

Spanner Insert the cable according to terminal number in the same manner as the indoor unit.

3.Connection If wiring is not correct, proper operation can not be carried out and controller may be damaged. 4.Attaching Drain-Elbow Fix the cable with a clamp.

4.Attaching Drain-Elbow

Manual background If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit.)