Installation instruction
8. Chink the wall and window with soft sponges or rubber bits in order to refrain from outside noises coming in or cooling air going out.
9. Air conditioner being fixed,insert the power plug in the socket, open the operation panel cover, turn the temperaure setting to "Test run", turn successively the mode selection to "Hi fan" and "Hi cool", "Lo cool" and "Lo fan", inspect the air conditioner's start and running performance.
10. If "Test run" is normal, turn mode selection to ''OFF", turn the temperature
Wall
Drain hose
setting to "9". Now the air conditioner is ready for use.
Fig. 5
The machine is adaptive in following situation
1. Applicable ambient temperature range:
| Indoor side | Maximum: | D.B/W.B | 32°C/23°C | |
Cooling | Minimum: | D.B/W.B | 18°C/14°C | ||
| |||||
|
|
|
| ||
Outdoor side | Maximum: | D.B/W.B | 43°C/26°C | ||
| |||||
| Minimum: | D.B | 18°C | ||
|
| ||||
|
|
|
|
|
2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.Power cable:3x1.5mm2
3.After installation, the power plug should be easily reached.
4.The wiring method should be in line with the local wiring standard.
12