Disposal of the condensed water
Generally there are two methods available on disposal of the condensed water:
1.Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditioner. (See Fig.1 ) In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the
heat exchanger, and evaporated and blown out from the machine. It can cool the heat exchanger radiator more quickly, and improve the energy efficiency of the conditioner. But the hitting noise by the fan at the outdoor side is relatively large.
2.Block the back hole of the conditioner with rubber lid and install outlet pipe fitting to the bottom hole, which can make the condensed water flow out from the bottom plate. (See Fig.2)
If necessary the above two methods can both have extra pipe added on the outlet pipe fitting. (available on the market).
(Refer to P15 for choosing these two modes.)
Fig.1 |
Outlet |
pipe fitting |
Back hole |
Rubber lid
Bottom plate hole
Fig.2
Rubber lid
Back hole
Outlet pipe fitting
Bottom plate hole
Cautions
Power cord: Be sure to use the exclusive power cord.
Change installation place: If
12