temperature sensor. Try to turn the adjusting stem of this value in the direction of the lower temperature graduation, and then check the contacts to see whether they are closed. If they are still not closed, dismantle the
d)Problems of motor and other electrical faults
i)Motor windings are damaged or there is a short circuited between turns
Analysis of Trouble
When motor windings are damaged or there the occurrence of a short circuit between turns, the fuse will be blown repeatedly, and the blowout particularly occurs at that instance where you close the knife switch.
Remedy
Check the terminals and the outer casing to see whether they are
ii)Control relay is faulty
Analysis of Trouble
Overheating, burns or wearing of control relay contacts will generally occur if this is true. All these will cause poor contact in electricity.
Remedy
Dismantle it for repairs, or replace it with a new one.
iii)Poor electric contractor in thermostat
Analysis of Trouble
Damaged contractor and leakage of temperature sensing agent will generally occur if this is true.
Remedy
Replace the old one with a new one.
iv)Check the terminals for loose connection and electric circuits for other abnormal phenomena.
e)Mechanical faults of compressor
i)Seizure of shaft