Halsey Taylor HRFG - ER*A Trouble Shooting & Maintenance, Hrfg - Er*A Hrfg - Sr*A Hrfg - Ser*A

Models: HRFG - ER*A HRFG - SR*A HRFG - SER*A

1 8
Download 8 pages 44.94 Kb
Page 8
Image 8
PARTS LIST

HRFG - ER*A HRFG - SR*A HRFG - SER*A

 

PARTS LIST

ITEM NO.

PARTNO.

DESCRIPTION

 

 

 

1

LK464

Drain

2

15005C

Retaining Nut

3

40038C

Strainer

4

40619C

Tailpipe Ferrule

5

45662C

Push Button

6

45738C

Push Button Sleeve

7

50986C

Regulator Holder

8

51544C

Bubbler

9

61313C

Regulator

10

70022C

Setscrew #6-32 x .31"

11

112627543890

Scr, #10-24 x 1/2 PH TR HD-Z

12

55996C

Strainer

13

56087C

Push Button - Extension

14

27201C

Bottom Cover Plate-Short

 

27658C

Bottom Cover Plate-Extended

15

26839C

Back Panel HRF-SER

 

26837C

Back Panel HRF-ER

 

26835C

Back Panel HRF-SR

16

40045C

Hex Nut

17

75554C

Insert - Threaded

18

70012C

Bubbler Locknut

19

27026C

Lower Panel HRF-SER

 

26833C

Lower Panel HRF-ER

20

70745C

Union - 3/8" x 1/4"

21

70870C

Union - 3/8"

22

70852C

Tee - 3/8"

23

55969C

Fountain-Galaxy Gray(HRFG-S)

 

56053C

Fountain-Galaxy Gray(HRFG-E)

 

56025C

Fountain-Black(HRFG-S)

 

56056C

Fountain-Black(HRFG-E)

24

100322740560

Gasket - Black

25

66399C

Tube Assy - Reg. to Bubbler

26

45736C

Nut - Regulator Mounting

 

 

 

TROUBLE SHOOTING & MAINTENANCE

Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.

CAUTION: DO NOT file or cut orifice material.

Stream Regulator: If orifice is free of material deposits, regulate flow as instructions on page 4(Step 9). If replace- ment is necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.4, Page 5) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".