OVLERQ*C OVLSRQ*C OVLESRQ*F OVLSERQ*F
Models
1. Cut a rectangular wall opening
| ||
| floor line (see Figure 7). The dimensions are required | |
| to obtain proper rim and bubbler heights for | |
| compliance with ANSI standard A117.1. | |
| 2. Reinforce the wall opening on all sides to adequately | |
| support the water fountain. This reinforcement must | |
| support up to 150 lbs. static load and provide a | |
| means for securing the frame assembly in place. | |
| NOTE: Building construction must allow for | |
| adequate air flow on both sides and top of | |
| remote chiller unit a minimum of 4” (102 | |
| mm) is required. | |
| 3. Install plumbing and electrical | |
| box for a (3) wire, 10 amp branch circuit is provided on | |
| the inside of the chiller. (Standard 120 Volts, 60 Hz, | |
| and single phase.) | |
Figure 6 – | 4. Remove frames and related hardware from | |
packaging. Release the two shelf rods by cutting | ||
| ||
| cable ties. Attach the two frames together through the | |
| upright supports with (4) 5/16” x 3/4” (19 mm) long | |
| bolts and nuts (not provided). Tighten securely. |
MAKE SURE FRAME CONFIGURATION MATCHES
THE COOLER TO BE INSTALLED
REVERSED CONFIGURATION:
HIGHER UNIT ON THE RIGHT
STANDARD CONFIGURATION:
HIGHER UNIT ON THE LEFT
Figure 7 –
97793C - 10/01