Quick Start
H3C S3100-SI Series Ethernet Switches Chapter 1 Product Overvie
w
1-18
After the switch is powered on, the A/L LED lights up initially. If
you press the MODE button, the D/S LED lights up. After that, if you
press the MODE button again within 45 seconds, the A/L LED lights up
again, or else the A/L LED automatically lights up after 45 seconds.
The MODE button is convenient for you to check the current
status of the ports as required. For example, if you want to learn the
Duplex and the Speed status of a port, you can first press the MODE
button to switch to the D/S LED, then observe the status (OFF, ON, or
flashing) of the two LEDs beside the port, and finally determine the
current status of the port according to the above table.
1.8 S3100-SI Series Technical Specifications 1.8.1 S3100-26T-SI/S3100-16T-SI/S3100-8T-SI
Ethernet Switch Technical Specifications
Table 1-3 S3100-26T-SI/S3100-16T-SI/S3100-8T-SI Ethernet
Switch technical specifications
Item S3100-26T-
SI S3100-16T-SI S3100-8T-SI
Physical
dimensions (H x
W x D)
42 x 436 x
240 mm (1.7
x 17.2 x 9.4
in)
42 x 436 x 200
mm (1.7 x
17.2 x 7.9 in)
42 x 326 x
200 mm (1.7
x 12.8 x 7.9
in)
Weight ≤ 3.2 kg (7.1 lb)