English
Modify the cartridge
The current ThermoBalance I cartridge has both a locator tab and a positioning pin. (The positioning pin is located on the back of the cartridge, and is not visible in this picture.)
An older ThermoBalance I/ThermoPlus rough does not have a notch for the locator tab.
Carefully file off the locator tab before install- ing a current cartridge into an old rough.
locator tab |
Justify the handle
Tools required: Thermometer
3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the water stream.
Turn the temperature control knob until the water coming out measures 100° on the thermometer.
Turn the water off using the lever part of the handle.
Use a 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove the handle from the valve (1).
Hold the lever in one hand. With the other hand, turn the temperature control knob approximately
½turn clockwise (2a). Then, without pressing inward on it, turn it
Reinstall the handle and tighten the set screw (3).
2
ab