To comply with the National Electric Code (NFPA70), and to provide additional protection from the risk of electrical shock, the
3.ALWAYS USE A 3 PRONG PLUG ADAPTER (not provided). This
Diagram.)
2 PRONG PLUG (31)
3 PRONG PLUG ADAPTER
FIGURE A | 115 VOLT OUTLET |
4.MAKE SURE THE POWER SWITCH IS IN THE “OFF” POSITION BEFORE PLUGGING IN THE POWER CORD.
5.DO NOT ABUSE THE POWER CORD. Do not use the Power Cord to pull the Plug from a power outlet. Keep Power Cord away from heat, oil, sharp edges, and moving parts. Replace a damaged Power Cord immediately. Route the Power Cord safely. Protect it from being damaged by other equipment in the work area. Do not route the Power Cord where it can be walked on or tripped over.
6.IF YOU USE AN EXTENSION CORD, MAKE SURE TO USE ONLY UL APPROVED CORDS HAVING THE CORRECT GAUGE AND LENGTH. (SEE FIGURE B.)
REQUIRED EXTENSION CORD GAUGE
Nameplate |
| Extension Cord Length |
|
| |||||
Amperes |
| 25’ | 50’ | 75’ | 100’ | 150’ | 200’ | ||
0 - 5 |
| 16 | 16 | 16 | 14 | 12 | 12 |
| |
5.1 | - 8 |
| 16 | 16 | 14 | 12 | 10 | - |
|
8.1 - 12 |
| 14 | 14 | 12 | 10 | - | - |
| |
12.1 | - 15 |
| 12 | 12 | 10 | 10 | - | - |
|
15.1 | - 20 |
| 10 | 10 | 10 | - | - | - |
|
|
|
|
|
|
|
|
|
|
|
FIGURE B