7.Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electri- cian before using it.
8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
(120 or 240 VOLT)
NAMEPLATE |
|
|
|
| EXTENSION CORD LENGTH |
| ||||||||
AMPERES |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
(at full load) | 25 Feet |
| 50 Feet |
| 75 Feet |
| 100 Feet | 150 Feet | ||||||
0 – 2.0 | 18 |
| 18 |
| 18 |
| 18 | 16 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2.1 | – 3.4 | 18 |
| 18 |
| 18 |
| 16 | 14 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
3.5 | – 5.0 | 18 |
| 18 |
| 16 |
| 14 | 12 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
5.1 | – 7.0 | 18 |
| 16 |
| 14 |
| 12 | 12 | |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
7.1 – 12.0 | 18 |
| 14 |
| 12 |
| 10 | - | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
12.1 | – 16.0 | 14 |
| 12 |
| 10 |
| - |
| - | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
16.1 | – 20.0 | 12 |
| 10 |
| - |
| - |
| - | ||||
|
|
|
|
|
|
|
|
|
| |||||
FIGURE C | * Based on limiting the line voltage drop to five volts at 150% of the rated amperes. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Symbology |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Double Insulated |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Canadian Standards Association |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| Underwriters Laboratories, Inc. |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
| V~ | Volts Alternating Current |
|
|
| |||||||
|
|
|
| A | Amperes |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||||||
|
|
| n0 xxxx/min. | No Load Revolutions per Minute (RPM) |
|
|
UNPACKING
When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.
SKU 42864 | For technical questions, please call | Page |