Harbor Freight Tools 66399 Troubleshooting, Problem Possible Causes Likely Solutions

Models: 66399

1 12
Download 12 pages 46.38 Kb
Page 9
Image 9

Note: Turn the Compressor upside

 

inflator nozzle bag, and slide Fuse

down to allow the oil to penetrate

 

holder back into slot. Fasten back

onto the piston rings.

 

into place with screws.

c. Slide the Front Cover back on and

8.

When the tool needs servicing, it

secure in place with the four screws.

 

should only be serviced by a qualified

6. If the Fuse (26) needs to be replaced,

 

technician.

snap off Fuse cover and then remove

 

 

and replace Fuse.

 

 

7. Slide out Fuse holder, replace old Fuse with new Fuse included in the

Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Decreased output.

1. Not enough air pressure and/

1.

Check for loose connections.

 

 

or air flow.

 

 

 

2.

Blocked air inlet Filter (3).

2.

Clean air inlet screen of buildup.

 

3.

Air leaking from loose housing

3.

Make sure housing and connections are

 

 

or connections.

 

properly assembled and tight.

 

4.

Mechanism contaminated.

4.

Have qualified technician clean and where

 

 

 

 

possible, lubricate mechanism.

Severe air

1. Cross-threaded housing

1.

Check for incorrect alignment and uneven

leakage.

 

components.

 

gaps. If cross-threaded, disassemble and

(Slight air leakage

 

 

 

replace damaged parts before use.

is normal,

2. Loose housing.

2.

Tighten housing assembly. If housing cannot

especially on older

 

 

 

be tightened properly, internal parts may be

tools.)

 

 

 

misaligned.

 

3.

Damaged valve or housing.

3.

Replace damaged components.

 

4.

Dirty, worn or damaged valve.

4.

Clean or replace valve assembly.

No output

1. Poor clamp connection.

1.

Clean clamps and reconnect properly.

 

2.

Power Switch in Off (O)

2.

Turn Power Switch to On (I) position.

 

 

position.

 

 

 

3.

Run-down battery.

3.

Recharge battery.

 

4.

Blown Fuse.

4.

Replace Fuse.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect from inflated item before service.

REV 10d

SKU 66399

For technical questions, please call 1-800-444-3353.

Page 9

Page 9
Image 9
Harbor Freight Tools 66399 operating instructions Troubleshooting, Problem Possible Causes Likely Solutions