Harbor Freight Tools 67697 Air Compressor Safety Warnings, 25’ 50’ 100’ 150’

Models: 67697

1 16
Download 16 pages 43.1 Kb
Page 5
Image 5

10.Use Safety Guard for Pulleys. The Air Compressor Pump Pulley (59), V-belt (not supplied), and motor pulley (not supplied) must be covered by a safety guard (not supplied) covering all moving elements before operation.

11.Avoid burns. The Cylinder (39), Cylinder Head (3) and Air Outlet components become very hot during operation. Do not touch.

Air Compressor Safety Warnings

1.Risk of fire or explosion - do not spray flammable liquid in a confined area or towards a hot surface. Spray area must be well-ventilated. Do not smoke while spraying or spray where spark or flame is present. Arcing parts - keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun.

2.Risk of bursting - do not adjust regulator higher than marked maximum pressure of attachment.

3.Risk of injury - do not direct air stream at people or animals.

4.Do not use to supply breathing air.

5.Do not leave compressor unattended for an extended period while plugged in. Unplug compressor after working.

6.Keep compressor well-ventilated. Do not cover compressor during use.

7.Drain compressor tank daily and after use. Internal rust causes tank failure and explosion.

8.Add correct amount of compressor oil before first use and every use. Operating with low or no oil causes permanent damage and voids warranty.

9.Do not remove the valve cover or adjust internal components.

10.Compressor head gets hot during operation. Do not touch it or allow children nearby during or immediately following operation.

11.Do not use the air hose to move the compressor.

12.Release the pressure in the storage tank before moving.

13.The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.

14.All air line components, including hoses, pipe, connectors, filters, etc., must be rated for a minimum working pressure of 150 PSI, or 150% of the maximum system pressure, whichever is greater.

15.USE OF AN EXTENSION CORD IS NOT RECOMMENDED. If you choose to use an extension cord, use the following guidelines:

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS

(120 VOLT)

NAMEPLATE

EXTENSION CORD

AMPERES

 

LENGTH

 

(at full load)

25’

50’

100’

150’

0 – 6

18

16

16

14

6.1 – 10

18

16

Do not use.

10.1 – 12

16

16

Do not use.

12.1 – 16

14

12

Do not use.

TABLE A

 

 

 

 

a. Make sure your extension cord is in good condition.

b. Be sure to use an extension cord which is heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and

SKU 67697

For technical questions, please call 1-800-444-3353.

Page 5

Page 5
Image 5
Harbor Freight Tools 67697 operating instructions Air Compressor Safety Warnings, 25’ 50’ 100’ 150’