the beams to the left on the horizontal line.
8 ft. | 8 ft. |
| a |
| b |
| 16 ft. |
4.If the distance between a and b is less than or equal to 2mm, the accuracy is within tolerance. Otherwise, take the instrument to a qualified technician for repair.
Vertical Beam Level Accuracy (End to End)
1.Set up the instrument with the Tripod, approximately 16 ft. from the wall. (The wall should be at least 17 ft. high). Please ensure the Rotary Base is approximately level.
2.Press both the horizontal and vertical buttons to project a laser cross on the wall, mark point A 8 ft. above the intersection of the beams on the vertical beam.
3.Use A as a starting point and nail one end of a string with plumb bob (not included) on A. The length of the string should be 16 ft.
4.Mark M1 16 ft. from point A on the string.
5.Mark M2 8 ft. below the intersection of the beams on the vertical line.
6.Measure the distance between M1 and M2.
7.If the distance is less than or equal to
2 mm, the accuracy is within tolerance. Otherwise, take the instrument to a qualified technician for repair.
After Using Laser
1.Detach Laser from Tripod.
2.Switch off both laser lines, horizontal and vertical. Check to see that both indicator LEDs are off.
3.Lock Pendulum Lock by tightening the screw in the center underneath the unit. After use the Pendulum Lock should be locked before the instrument is put away in the Carrying Case.
4.Note: When the Pendulum Lock is unlocked, do not shake or strike the instrument, otherwise the mechanism inside could be damaged.
5.Warning: Always make certain the Laser is OFF before adjusting or changing batteries.
Page 6 | For technical questions, please call | SKU 92703 |