Table A
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
(120 VOLT)
NAMEPLATE |
|
|
|
|
| |
AMPERES |
| EXTENSION CORD LENGTH |
| |||
(At Full Load) |
|
|
|
|
| |
|
| 25 | 50 | 75 | 100 | 150 |
|
| Feet | Feet | Feet | Feet | Feet |
0 – 2.0 | 18 | 18 | 18 | 18 | 16 | |
2.1 | – 3.4 | 18 | 18 | 18 | 16 | 14 |
3.5 | – 5.0 | 18 | 18 | 16 | 14 | 12 |
5.1 | – 7.0 | 18 | 16 | 14 | 12 | 12 |
7.1 – 12.0 | 16 | 14 | 12 | 10 | - | |
12.1 | – 16.0 | 14 | 12 | 10 | - | - |
16.1 | – 20.0 | 12 | 10 | - | - | - |
* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.