To Attach An Air Connector:

1.Attach a 1/4” Connector (not includ- ed) to the Adapter (82) prior to opera- tion.

2.Wrap about 3” of pipe thread seal tape (not included) onto threads of the Connector before attaching it to the Adapter.

OPERATING INSTRUCTIONS

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Inspect tool before use, looking for damaged, loose, and missing parts. If any problems are found, do not use tool until repaired.

Loading Nails and Staples

TO PREVENT SERIOUS INJURY

FROM ACCIDENTAL OPERATION: Detach the air supply, safely discharge any residual air pressure in the tool, and release the throttle and/or turn the switch to its off position before performing any inspection, maintenance, or cleaning procedures.

TO PREVENT SERIOUS INJURY: Do not adjust or tamper with any control or component in a way not specifically explained within manual. Improper adjustment can result in tool failure or other serious hazards.

WARNING! Disconnect the Floor Nailer from the air compressor when- ever loading or servicing. After dis- connecting the Floor Nailer from the air compressor, there could still be enough air pressure to fire the Nailer. After the air hose is disconnected, always fire the Nailer into scrap wood repeatedly to make sure all of the compressed air is expended.

Loading Cleat Nails:

Safety

Lock (54)

Side Load

Magazine

(61)Magazine

(52)

Pusher (56)

1.Pull the Pusher (56) back to end of Magazine (52). Lock Pusher in place by using Safety Lock (54). Then pull Side Load Magazine (61) back.

2.Place full clip of desired fasteners into Magazine (61) from the side. Up to 100 Cleat Nails may be loaded into Nailer.