10PP38+ Pellet Stove3-90-08422R27_09/12
#2 Preferred method This method also provides excellent venting for
normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
shouldbe threeto vefeet highand at leastthree
inches from a combustible wall. This vertical section
will provide natural draft in the event of a power failure.
If the stove is installed below grade be sure the
vent termination is at least 18" above grade. The outlet
must also be 1 foot from the house/building.
Note: Do not place joints within wall pass-
throughs.
#1 Preferred method This method provides excellent venting for normal
operation and allows the stove to be installed closest
to the wall. Two inches from the wall is safe; however,
four inches allows better access to remove the rear
panel. The vertical portion of the vent should be three
tovefeethigh.Thisverticalsectionwill helpprovide
natural draft in the event of a power failure. note: do
not place joints within wall pass-throughs.
venting
36" min
clearance to any
combustible
material
12" min. wall to outlet
caution
Keep combustible materials (such as grass, leaves,
etc.) at least 3 feet away from the ue outlet on the
outside of the building.
Fig. 8
3 ft.
to
combustibles
3 ft.
to combustibles
Fig. 9
3 ft.
to
combustibles
3 ft.
to combustibles