Clarity B Vent .

Gas Heater Specifications

Tested to ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA 2.17-M91.

 

NATURAL GAS

PROPANE

Input Rating (Btu/hr) (0-1375 m)

40,000

 

40,000

Min. Input Rating (Btu/hr) (0-1375 m)

27,000

 

28,000

Injector Sizes (DMS) (front/center/rear (0-1375 m)

47/56/39

56/71/53

Manifold Pressure (in w.c./kPa)

3.5/0.87

 

10.0/2.49

Minimum Manifold Pressure (in w.c./kPa)

1.7/0.42

 

5.9/1.47

Minimum Inlet Pressure (in w.c./kPa)

5.0/1.25

 

11.0/2.74

Maximum Output (Btu/hr) (0-1375 m)

30,500

 

30,800

AFUE (seasonal efficiency; minimum venting)

65.2%

 

66.0%

Steady State Efficiency (max. input, blower on High)

78.2%

 

79.7% .

MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION

 

Unit to left sidewall

9 in.

(230 mm)

 

Unit to right sidewall

9 in.

(230 mm)

 

Unit corner to walls

4 in.

(100 mm)

 

Rear of unit to back wall

3 in.

(75 mm) .

 

(measured from rear of draft hood heat shield)

 

 

 

Unit to alcove ceiling

18 in.

(460 mm)

 

Maximum alcove depth

14 in.

(355 mm)

 

Electrical Rating: 120 Volts, 60 Hz., Less than 1 Amp

Stove Weight: 234 lbs.