Due to high temperatures, the Clarity Vented Gas Heater should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the haz- ards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the Clarity Vented Gas Heater.
Clothing or other flammable materials should not be placed on or near the Clarity Vented Gas Heater.
Clearance from corner of unit to walls
Installation
CLEARANCES
The following clearances to combustibles must be
observed: |
|
|
Unit to left sidewall | 9" | (230 mm) |
Unit to right sidewall | 9" | (230 mm) |
Unit corner to walls | 4" | (100 mm) |
Rear of unit to back wall | 3" | (75 mm) |
(measured from rear of draft hood to wall) |
| |
Unit to alcove ceiling | 18" | (460 mm) |
Maximum alcove depth | 14" | (355 mm) |
Sidewall Clearance
Clearance to Back wall
Clearance to alcove ceiling
Maximum alcove depth
In addition to these clearances, adequate accessibil- ity clearance for servicing and proper operation must be maintained.
Do not in any way obstruct the combustion air inlets that are located under the heater.
If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel ex- tending at least the full width and depth of the appliance.