LIGHTING AND OPERATION

MANUAL IGNITION

1.STOP! Read the safety information on the top of page 23.

2.Locate the valve on the back of the stove. Turn the main valve knob to the OFF, full clockwise position.

3.Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you smell gas, STOP! Follow A in the safety information on page 23. If you don’t smell gas, proceed to Step 4.

4.Visually locate the pilot at the center rear of the firebox. Refer to Fig. 3 below.

5.With the MAN-knob in MAN position, a manual pilot valve operator is accessible (Refer to Fig. 1).

Fully push down the manual pilot valve operator using a small screwdriver or pen tip and hold in to start pilot gas flow. Immediately light the pilot by rapidly depressing the piezo igniter button on the valve (See Fig. 1). Once the pilot flame is observed, continue to hold in the manual pilot valve operator for about one (1) minute. Release the manual pilot valve operator. If the pilot does not stay lit, repeat steps 2 through 5.

Note: If the pilot does not stay lit after several tries, turn the main valve knob to OFF and pro- ceed to step 7.

6.Turn the MAN-knob to the ON, full counterclockwise position.

7.If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO MAIN BURNER” and call your service technician or gas supplier.

TO TURN OFF GAS TO MAIN BURNER

1.Press the OFF button on the remote (if available).

2.Turn the main valve knob to the OFF full clockwise position.

LIGHTING INSTRUCTIONS - COOKING BURNER

1.Stop! Read the safety information shown on the top of page 23.

2.Locate the cooking burner gas control knob at the top right rear of the appliance. Refer to Fig. 4 below for more information.

3.With the valve in the OFF position, push down on the knob and turn counterclockwise to the H (High) position. The cooking burner has a built-in electronic ignition system and the burner will ignite automatically. If the burner does not light within five (5) seconds, turn the knob to the OFF, full clock-

wise position and call your service technician or gas supplier.

4.Adjust the burner for the desired cooking heat level.

TO TURN OFF GAS TO COOKING BURNER

1. To turn the cooking burner off, turn the knob to the OFF, full clockwise position.