Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System Specifications

Models: FireLuxe Direct Vent Gas Stove With Top Cooking Burner System

1 32
Download 32 pages 23.52 Kb
Page 5
Image 5

SPECIFICATIONS

MAIN BURNER

Natural Gas

Propane (LP)

Input Rating-Btu/hr

36000

36000

Min. Input-Btu/hr

23000

23000

Orifice-DMS

#34

#50

COOKING BURNER

 

 

Input Rating-Btu/hr

12000

12000

Min. Input-Btu/hr

3500

3500

Orifice-DMS

#52

#58

GAS SUPPLY

 

 

Manifold Pressure

4.5”w.c./1.3kPa

10.0”w.c./2.5kPa

Min. Supply Pressure

5.0”w.c./1.3kPa

11.0”w.c./2.8kPa

Max. Supply Pressure

10.0”w.c./1.8kPa

13.0”w.c./3.3kPa

Annual Fuel Utilization Efficiency (AFUE)

72.7%

74.9%

Steady State Efficiency

73.4%

75.6%

It is recommended that the pilot flame be turned off if the appliance will not be in use for an extended period of time.

This appliance is equipped for use with the fuel type indicated on the rating plate. Fuel conversion kits that include the necessary parts and instructions are available from your installer, dealer or Harman Stove Co.

This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2005 • CSA 2.33-2005 Vented Gas Fireplace Heaters and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.

The FireLuxe is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.