P61A-2 MANUAL START UP

Fig. 20

Fig. 19

See Note 7. 1"

Fig. 21

1.Fines are small pieces of broken pellets (sawdust). Fines do not flow easily and often build up on the hopper funnel bottom angles. These fines can be pushed into the feeder opening and then fill the hopper with pellets. As the system works, they will be burned.

2.The "TEST" cycle will operate the feeder motor for exactly one minute. Turning to "TEST" again and again may purge too much fuel into the burn pot causing excessive smoke on start-up.

3.The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open.

4.Adjust Feed Rate. If this is your first fire or you are trying different pellets, set the feed adjuster to #4, Fig. 19. This is a conservative number and will probably need to be increased. After you know a feed rate setting that works well, use that setting. Remember, if your feed rate is too high you may waste fuel.

5.This is usually a weekly maintence procedure. Cleaning the burn pot with the scraper with a small amount of new fuel in the bottom is not a problem. First, scrape the ashes on the front of the burn pot into the ash pan. Then scrape the holed surface downward into the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder.

6.The ash pan can hold the ashes from approximately 1 ton of premium fuel. This means the ashes will only need to be emptied a few times a year.

7.Setting the feed adjuster # for maximum burn: With the unit burning in "AUTO", turn to "Stove Mode" and put the fan on "H". Set the Temperature Dial to #7. Allow the unit to burn for about

30minutes and check ash on front of burn pot. Fig. 21. If the ash line is larger than 1", turn the feed adjuster from #3 to #4. Allow another 30 minutes of burn time and check again. If , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only a maximum burn rate and at most normal settings the ash bed will be larger.

Starting First Fire

Ignitor Switch to"MANUAL" (down position)

Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit.

1.Turn FEED ADJUSTER to desired feed rate. No. 4 is good for most pellets.4

2.Turn the MODE SELECTOR to ìOFFî and then to the desired mode. This will reset control and start the combustion mo- tor.

3.Turn the TEMPERATURE DIAL to the desired setting.

4.Clean burn pot with scraper if necessary.5

5.Fill burn pot with pellets, only level with front edge. (Do Not Over Fill).

6.Add starting gel on top of the pellets. Stir gel into pellets for fast lighting.

7.Light starting gel with a match, and close the door. Operation will begin when the fire reaches the proper temperature.3

8.Fill hopper with pellets and remove ashes as required.1, 6

Warning

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP"AFIRE IN THIS HEATER. KEEPALLSUCH LIQUIDS WELLAWAY FROM THE HEATER WHILE IN USE".

P61A Pellet Stove 15

Page 15
Image 15
Harman Stove Company owner manual P61A-2 Manual Start UP, Starting First Fire Ignitor Switch toMANUAL down position

P61A-2 specifications

The Harman Stove Company P61A-2 is a premier pellet stove that exemplifies modern design and efficient heating technology. Known for its high performance and user-friendly features, this model is a popular choice among homeowners seeking an eco-friendly heating solution.

One of the standout features of the P61A-2 is its impressive heating capacity. With the ability to produce up to 51,000 BTUs (British Thermal Units), it can effectively heat spaces of up to 2,800 square feet. This makes the stove suitable for both large living areas and open floor plans, ensuring consistent warmth during the chilly months.

The P61A-2 also boasts a sleek, contemporary design that fits seamlessly into various home decors. Available in several finishes, including classic black and rich bronze, it enhances the aesthetic appeal of any room. Its compact size allows for versatile installation options, whether it's in a corner or as a freestanding unit.

In terms of technology, the Harman P61A-2 features an advanced pellet feed system that maximizes efficiency and minimizes waste. This system ensures a steady supply of pellets to the burn pot, optimizing combustion and resulting in high efficiency ratings. The stove has an automatic ignition system, allowing users to easily start it with the push of a button, enhancing convenience and reducing the hassle often associated with traditional wood-burning stoves.

The stove is equipped with a unique heat exchanger and blower system that enhances heat distribution, ensuring warmth is circulated evenly throughout the room. Its adjustable variable-speed blower allows users to customize airflow, catering to their specific heating needs.

Additionally, the P61A-2 is designed with an easy-to-use control panel, providing options for temperature setting, operating modes, and diagnostics. This user-friendly interface allows for effortless operation, even for those new to pellet stoves.

Maintenance is simplified with the P61A-2, as it includes an easy-access clean-out door for quick ash disposal and a removable burn pot for thorough cleaning. The durable construction and high-quality materials ensure longevity, making the P61A-2 a reliable heating solution for years to come.

In summary, the Harman Stove Company P61A-2 combines powerful heating capabilities with innovative technology, a stylish design, and user-friendly features, making it a top choice for efficient home heating.