6P61A!!Pellet!Stove
Venting
Requirements!for!Terminating!the!Venting
WARNING:!Venting!terminals!must!not!be!re-
cessed!into!a!wall!or!siding.
NOTE:!Only!PL!vent!pipe!wall!pass-throughs
and!fire!stops!should!be!used!when!venting!through
combustible!materials.
NOTE:!Always!take!into!consideration!the!ef-
fect!!the!prevailing!wind!direction!or!other!wind!cur-
rents!will!cause!with!flyash!and!/or!smoke!when!plac-
ing!the!termination.
In!addition,!the!following!must!be!observed:
A.!The!clearance!above!grade!!must!be!a!mini-
mum!of!18".1
B.!The!clearance!to!a!window!or!door!that!may
be!opened!must!be!a!minimum!of!48"!to!the!side,
48"!below!the!window/door,!and!12"!above!the!win-
dow/door.1
(!with!outside!air!installed,!18î!)
C.!A!12"!!clearance!to!a!permanently!closed
window!!is!!recommended!to!prevent!condensation
on!the!window.
D.!The!vertical!clearance!to!a!ventilated!soffit
located!above!the!terminal!within!a!horizontal!dis-
tance!of!2!feet!(60!cm)!from!the!center-line!of!the
terminal!!must!be!a!minimum!of!18".
E.!The!clearance!to!an!unventilated!soffit!!must
be!a!minimum!of!12".
F.!The!clearance!to!an!outside!corner!is!11"
from!center!of!pipe.
G.!The!clearance!to!an!inside!corner!is!12".
H.!!A!vent!must!not!be!installed!within!3!feet!(90
cm)!above!a!gas!meter/regulator!assembly!when
measured!from!the!horizontal!center-line!of!the!regu-
lator.1
I.!The!clearance!to!service!regulator!vent!outlet
must!be!a!minimum!of!6!feet.1
J.!The!clearance!to!a!non-mechanical!air!sup-
ply!inlet!to!the!building!or!the!combustion!air!inlet!to
any!other!appliance!must!be!a!minimum!of!48î.1
K.!The!clearance!to!a!mechanical!air!supply
inlet!must!be!a!minimum!of!10!feet.1
(with!outside!air!installed,!6!feet!)
L.!The!clearance!above!a!paved!sidewalk!or!a
paved!driveway!located!on!public!property!must!be
a!minimum!of!!7!feet.1,2
!M.!The!clearance!under!a!veranda,!porch,!deck
or!balcony!must!be!a!minimum!of!12!inches.1,3
NOTE:!!The!clearance!to!vegetation!and!other
exterior!combustibles!such!as!mulch!is!36î!as!mea-
sured!from!the!center!of!the!outlet!or!cap.!This!36î
radius!continues!to!grade!or!a!minimum!of!7!feet
below!the!outlet.
1Certain!Canadian!and!or!!Local!codes!or!regu-
lations!may!require!different!clearances.
2A!vent!shall!not!terminate!directly!above!a!side-
walk!or!paved!driveway!which!is!located!between
two!single!†family!dwellings!and!serves!both!dwell-
ings.
3Only!permitted!if!veranda,!porch,!deck,!or!bal-
cony!is!fully!open!on!a!minimum!of!!2!sides!beneath
the!floor.
NOTE:!Where!passage!through!a!wall,!or
partition!of!combustible!construction!is!desired,
the!installation!shall!conform!to!CAN/CSA-B365.
(if!in!!Canada)
VA
=!Vent!terminal =!Air!supply!inlet
Fixed
Closed
Openable
Openable Fixed
Closed
Inside!Corner
Detail
=!Area!where!terminal!is!not!permitted