SF2600 Burner Set Up

 

SF2600 Burner Set Up

 

 

SF2600 Oil Burner Setup

 

Nozzle

80 Degree Solid Cone

Off Cycle Damper Setting (B)

No.1 (as low as it goes

Flamelock Setting (A)

No. 1

Combustion Air (C)

No. 1 to 1¼

Draft - (Inches of water column)

.06 to .08

Tests for CO² must be made without a fire in the wood/ coal firebox, and with all doors and draft controls completely closed. The burner should be fired for several minutes prior to taking a reading. Normal CO² reading is 11 to 12 with a stack temperature of 300 degrees or less. This would give you an efficiency of 84 to 85 percent.