Furnace Installation

To ensure a safe installation, it is recommended that this furnace be installed by a qualified installer.

The sheet metal top and sides can be easily removed to reduce the chance of dents or scratches on the painted surfaces.

To remove the sheet metal, first lift off the top section. Now, the sides can be removed by lifting up and out away from the furnace.

To lighten the SF2600, the oil burner heat exchanger should be removed. Do so by first removing the sheet metal as described above. Remove the front sheet metal by first removing the burner collar. Now remove the the two long bolts on each side of the heat exchanger. (Figure B) The entire unit can now be lifted off and moved separately.

Caution: This furnace must not be installed closer than 24 inches at the sides and 30 inches from the rear to combustible materials. The unit may

only be installed on a non-combustible floor surface such as concrete floor or concrete pad on dirt floor. The hot air plenum must be a minimum of 2 inches from the ceiling or other combustibles above the plenum.

Locate the furnace as close to the chimney as possible while still maintaining the above clearances. No more than 8 feet of stovepipe should be used, including two or less 90° elbows. All horizontal runs of pipe should have a minimum 1/4 in. rise per foot. All stove pipe must be 24 gauge or thicker.

When re-installing the heat exchanger, inspect the gasket around the furnace opening, and replace if necessary. (Figure A) Place the heat exchanger in position and secure with the long bolts and nuts. Be sure the gasket is compressed evenly.

Re-install the sheet metal by sliding the groove on the bottom of each side panel over the steel lip on the furnace. The top sheet metal piece holds the sides in place. The SF2600 front cover gets installed by angling the bottom edge over the lip on the top of the firebox. The side edges must slide into the grooves on each side and pushed in flush with the sides and top. This front piece is held in place by the black ring which gets tightened around the burner pipe. Do not over tighten as this will push the sheet metal in too far.

Inspect Gasket prior to re- installing heat exchanger.

Figure A

(4) 12in. bolts, two on each side, attach the heat exchanger to the furnace.

Figure B

5

Page 5
Image 5
Harman Stove Company SF1500A manual Furnace Installation, Figure a

SF1500A specifications

The Harman Stove Company has established itself as a leader in the heating industry, known for its innovative and efficient wood and pellet stoves. The SF series, including models SF2600A, SF1500A, SF3500A, and SF2500A, showcases the company's commitment to high-quality craftsmanship and cutting-edge technology.

The SF2600A stands out with its robust heat output, designed for larger spaces. With a capacity to heat up to 3,000 square feet, it features a large firebox capable of accommodating extended burns, which means less frequent refueling. The CleanStart technology ensures that the stove ignites quickly and efficiently, minimizing smoke emissions and energy waste. Users will appreciate the integrated air wash system, which keeps the glass clean, providing an unobstructed view of the flames.

Meanwhile, the SF1500A serves as an excellent choice for smaller homes or cozy spaces, heating areas up to 1,800 square feet. Its compact design does not compromise on performance. The model also incorporates Harman's advanced combustion technology, which optimizes airflow for a cleaner burn. This efficiency not only helps in reducing heating costs but also contributes to a more environmentally-friendly operation.

The SF3500A is engineered for those who demand maximum warmth and efficiency. With a substantial heat output, it can easily heat areas exceeding 3,500 square feet. This model integrates a state-of-the-art digital control board that allows users to manage their heating needs effortlessly, providing options for programmable settings and real-time monitoring. It also boasts a high-efficiency rating, ensuring users get the most from their fuel, with longer burn times and minimal ash production.

Lastly, the SF2500A offers a balanced approach, capable of heating spaces up to 2,500 square feet. It features adjustable air controls, enabling users to customize their heating experience based on personal preference. The built-in diagnostics system helps troubleshoot potential issues, providing peace of mind for homeowners. With elegant styling and various finishing options, the SF2500A can seamlessly integrate into any home décor while delivering dependable warmth.

Each model in the Harman SF series exemplifies durability, performance, and user-friendly operation, making them ideal for anyone seeking a reliable heating solution in today's energy-conscious landscape.