9.0 Fan Wiring with Remote

This appliance may be used with an RC200 or RC300 remote control. See Figure 7.

1.Remove cord assembly spades from rheostat and sensor switch.

NOTICE: Fan speed and operation are controlled by the remote control. The sensor switch and rheostat are no longer needed.

2.Plug two cord assembly spade connectors together.

3.Unplug fan cord assembly from standard cord assembly.

4.Install fuse wire assembly in series between the black lead wires of the fan cord and black lead wire on each blower. See Figure 7.

5.Plug fan cord assembly into AUX300 module.

6.Plug AUX300 module into the standard cord assembly.

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE.

NOTE: USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL (FAN BLADES).

BLOWER

PLUG

 

120V EXISTING

STEP 5

 

OUTLET

 

STEPS

 

1 & 2

 

STEPS

 

3 & 5

 

SENSOR SWITCH

WHT (2)

 

GRN (2)

 

BLK (2)

 

BLK (2)

SPEED CONTROL

GRN (2)

(RHEOSTAT)

BLK (2)

 

NOTE: SENSOR SWITCH AND

RHEOSTAT SPEED CONTROL MUST

BE REMOVED FROM CIRCUIT IF

SYSTEM IS CONTROLLED WITH

RC200/300 REMOTE.

PLUG INTO 120V

EXISTING OUTLET

DC REGULATOR

RECEPTICLE

TO CONTROL

MODULE

BLK

BLK

BLOWER

RECEPTICLE

AUX 300 MODULE

FAN

WHT

GRN

BLK

BLK

GRN

WHT

FUSE WIRE ASSEMBLY

FUSE WIRE ASSEMBLY

BLK

GRN

BLK

BLOWERS

BLK

GRN

BLK

Figure 7. Fan Wiring Diagram - Metal Insert with RC200/RC300 Remote

Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11

5

Page 5
Image 5