10.0 INSTALLING THE BLOWER (FireBrick Inserts)

1.Remove appliance from wall.

2.Disconnect power by shutting off circuit breaker or unplugging appliance power cord from its receptacle.

3.Remove access panel from lower rear of the fireplace insert. See Figure 8.

4.Attach blower to base with two screws. See Figure

9.Connect white and green wires from blower wire assembly to each blower. See Figure 9. Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower. See Figure

5.Insert plug from blower cable assembly into AUX300 receptacle. See Figure 10.

6.Bundle and zip tie loose wires to keep them from con- tacting blower impeller blades

7.Position the right and left blower assembly into the rear opening. Take care to ensure that blower housing or its motor is clear of any adjacent metal. This will ensure that no undue noise occurs during blower operation.

8.Reinstall access panel.

9.Reconnect power to the insert and install into wall.

BLOWER

ACCESS PANEL

POWER CORD

Figure 8. Remove Access Panel

Figure 9. Attach Blower to Base

6

Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11

Page 6
Image 6
Heart & Home Collectables GFK-210 manual Installing the Blower FireBrick Inserts, Remove Access Panel