11 Troubleshooting

With proper installation, operation and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

A. Intellifire Ignition System

 

Symptom

 

Possible Causes

Corrective Actions

1.

The ignitor/module makes

A.

Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected to the

 

noise, but no spark.

 

 

correct terminals on the module and the pilot assembly. Reversed wires at the module

 

 

 

 

may cause the system to make a sparking noise, but the spark may not be present at

 

 

 

 

pilot hood.

 

 

B.

Loose connections or

Verify there are no loose connections or electrical shorts in wiring from module to

 

 

 

electrical shorts in the

pilot assembly. The rod closest to the pilot hood should be ignitor. Verify connections

 

 

 

wiring.

underneath pilot assembly are tight; also verify the connections are not grounding out

 

 

 

 

to the metal chassis, pilot burner, pilot enclosure, mesh screen if present, or any other

 

 

 

 

metal object.

 

 

C.

Ignitor gap is too large.

Verify gap of ignitor to pilot hood. The gap should be approximately .17 in. or 1/8 in.

 

 

D.

Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitor wire “I”

 

 

 

 

from module. Place ON/OFF rocker switch or wall switch in ON position. Hold ground

 

 

 

 

wire about 3/16 in. away from “I” terminal on module. If there is no spark at “I” terminal,

 

 

 

 

module must be replaced. If there is a spark at “I” terminal, module is fine. Inspect pilot

 

 

 

 

assembly for shorted sparker wire or cracked insulator around electrode.

2.

Pilots won’t light, there is

A.

Transformer installed

Verify that transformer is installed and plugged into module. Check voltage of

 

no noise or spark.

 

incorrectly.

transformer under load at space connection on module with ON/OFF switch in ON

 

 

 

 

position. Acceptable readings of a good transformer are between 3.2 and 2.8 volts AC.

 

 

B.

A shorted or loose

Remove and reinstall the wiring harness that plugs into module. Verify there is a tight

 

 

 

connection in wiring

fit. Verify pilot assembly wiring to module. Remove and verify continuity of each wire in

 

 

 

configuration or wiring

wiring harness.

 

 

 

harness.

 

 

 

C.

Improper wall switch

Verify wall switch is wired correctly.

 

 

 

wiring.

 

 

 

D.

Module not grounded.

Verify black ground wire from module wire harness is grounded to metal chassis of

 

 

 

 

appliance.

 

 

E.

Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitor wire “I”

 

 

 

 

from module. Place ON/OFF rocker switch or wall switch in ON position. Hold ground

 

 

 

 

wire about 3/16 in. away from “I” terminal on module. If there is no spark at “I” terminal

 

 

 

 

module must be replaced. If there is a spark at “I” terminal, module is fine. Inspect pilot

 

 

 

 

assembly for shorted sparker wire or cracked insulator around electrode.

3.

Pilot lights but continues

A.

A shorted or loose

Verify all connections to wiring diagram in manual. Verify connections underneath pilot

 

to spark, and main burner

 

connection in sensor rod.

assembly are tight. Verify connections are not grounding out to metal chassis, pilot

 

will not ignite. (If the pilot

 

 

burner, pilot enclosure or screen if present, or any other metal object.

 

continues to spark after

B.

Poor flame rectification or

Verify flame is engulfing sensor rod. If the pilot assembly does not have a ground

 

the pilot flame has been

 

 

contaminated sensor rod.

strap, consider installing one to increase flame rectification. Verify correct pilot orifice

 

lit, flame rectification has

 

 

 

 

is installed and inlet gas specifications are met. Flame carries rectification current, not

 

not occurred.)

 

 

 

 

 

the gas. If flame lifts from pilot hood, the circuit is broken. A wrong orifice or too high

 

 

 

 

 

 

 

 

an inlet pressure can cause pilot flame to lift. The sensor rod may be contaminated.

 

 

 

 

Clean sensor rod with emery cloth.

 

 

C.

Module is not grounded.

Verify that module is securely grounded to metal chassis of appliance. Verify that the

 

 

 

 

wire harness is firmly connected to module.

 

 

D.

Damaged pilot assembly

Verify that ceramic insulator around the sensor rod is not cracked, damaged, or loose.

 

 

 

or dirty sensor rod.

Verify connection from sensor rod to white sensor wire. Clean sensor rod with emery

 

 

 

 

cloth to remove any contaminants that may have accumulated on sensor rod. Verify

 

 

 

 

continuity with a multimeter with ohms set at lowest range.

 

 

E.

Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitor wire “I”

 

 

 

 

from module. Place ON/OFF rocker switch or wall switch in ON position. Hold ground

 

 

 

 

wire about 3/16 in. away from “I” terminal on module. If there is no spark at “I”

 

 

 

 

terminal, module must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode.

4.

Pilot sparks, but pilot will

A.

Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet pressure reading is

 

not light.

 

 

within acceptable limits, inlet pressure must not exceed 14 in. w.c.

 

 

B.

Ignitor gap is too large.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

 

 

C.

Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

D.

Module voltage output/

Replace module.

 

 

 

valve/pilot solenoid ohms

 

 

 

 

readings.

 

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 • Rev J 11/08 23

Page 23
Image 23
Hearth and Home Technologies 42-B Troubleshooting, Intellifire Ignition System, Symptom Possible Causes Corrective Actions

42H-B, 42-B specifications

Hearth and Home Technologies has long been a leader in the realm of home heating and comfort solutions, and their 42-B and 42H-B models exemplify this commitment to quality and innovation. These models are designed to meet modern heating needs while providing an aesthetic appeal that enhances any living space.

One of the standout features of the 42-B and 42H-B is their impressive heating capabilities. With a BTU output that can efficiently heat large areas, these units are perfect for homeowners looking to maintain a comfortable environment during the colder months. The ability to generate substantial heat without consuming excessive fuel has made these models a preferred choice among energy-conscious consumers.

In addition to their efficient heating, the 42-B and 42H-B also incorporate advanced venting technologies. These models are designed with flexible venting options, allowing for both direct vent and B-vent installation. This versatility not only simplifies the installation process but also provides homeowners with more options in terms of their heating setup. Whether looking to install in a new build or retrofit an existing space, the 42-B and 42H-B fit seamlessly into various configurations.

Another notable feature of these models is their aesthetic design. Hearth and Home Technologies understands the importance of appearance in maintaining the overall decor of a home. The 42-B and 42H-B come with customizable front options, ensuring that each unit can match the individual style of a home. From traditional to contemporary looks, these models can complement any interior with elegance and charm.

Safety is a top priority for Hearth and Home Technologies, and the 42-B and 42H-B have been designed with several safety features to ensure peace of mind. The units come equipped with a glass front that remains cool to the touch, preventing accidental burns, and advanced safety shutoff mechanisms that activate in the event of a malfunction, ensuring that homeowners can enjoy their heating solutions without worry.

In conclusion, the Hearth and Home Technologies 42-B and 42H-B models combine efficiency, safety, versatility, and style. They offer an exceptional heating experience, making them an attractive option for anyone looking to enhance their home comfort. With their reliable performance and elegant appearance, these units stand as a testament to Hearth and Home Technologies' dedication to quality in the home heating market.