B. Maintenance and Service Tasks:

Inspect

 

Maintenance Tasks

Doors, surrounds and

1.

Inspect for scratches and nicks that can lead to breakage when exposed to heat.

fronts

 

 

2.

Verify no obstructions to airflow through the louvers.

 

 

 

 

 

3.

Verify proper clearance to combustible household objects is maintained.

 

 

 

Glass assembly and

1.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

glass

 

 

2.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

3.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact and

 

 

operating properly. Replace as necessary.

 

4.

Clean glass using a nonabrasive cleaner such as Brasso®. Replace glass assembly if severely coated with

 

 

silicate deposits that cannot be removed.

 

 

 

Valve compartment and

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that

firebox top

 

have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

2.

Replace appliance is firebox has been perforated.

 

 

 

Burner ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

3.

Replace rockwool with new dime-sized and shaped pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting or other flame problems.

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

10.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery cloth

 

 

or replace as required.

 

11.

Verify millivolt output. Replace as necessary.

 

 

 

Remote controls

1.

Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

3.

If appliance will not be used for a long period of time, verify batteries have been removed from battery back-up

 

 

in IPI systems to prevent premature battery failure or leaking.

 

 

 

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 • Rev J 11/08 27

Page 27
Image 27
Hearth and Home Technologies 42-B, 42H-B owner manual Maintenance and Service Tasks, Inspect Maintenance Tasks

42H-B, 42-B specifications

Hearth and Home Technologies has long been a leader in the realm of home heating and comfort solutions, and their 42-B and 42H-B models exemplify this commitment to quality and innovation. These models are designed to meet modern heating needs while providing an aesthetic appeal that enhances any living space.

One of the standout features of the 42-B and 42H-B is their impressive heating capabilities. With a BTU output that can efficiently heat large areas, these units are perfect for homeowners looking to maintain a comfortable environment during the colder months. The ability to generate substantial heat without consuming excessive fuel has made these models a preferred choice among energy-conscious consumers.

In addition to their efficient heating, the 42-B and 42H-B also incorporate advanced venting technologies. These models are designed with flexible venting options, allowing for both direct vent and B-vent installation. This versatility not only simplifies the installation process but also provides homeowners with more options in terms of their heating setup. Whether looking to install in a new build or retrofit an existing space, the 42-B and 42H-B fit seamlessly into various configurations.

Another notable feature of these models is their aesthetic design. Hearth and Home Technologies understands the importance of appearance in maintaining the overall decor of a home. The 42-B and 42H-B come with customizable front options, ensuring that each unit can match the individual style of a home. From traditional to contemporary looks, these models can complement any interior with elegance and charm.

Safety is a top priority for Hearth and Home Technologies, and the 42-B and 42H-B have been designed with several safety features to ensure peace of mind. The units come equipped with a glass front that remains cool to the touch, preventing accidental burns, and advanced safety shutoff mechanisms that activate in the event of a malfunction, ensuring that homeowners can enjoy their heating solutions without worry.

In conclusion, the Hearth and Home Technologies 42-B and 42H-B models combine efficiency, safety, versatility, and style. They offer an exceptional heating experience, making them an attractive option for anyone looking to enhance their home comfort. With their reliable performance and elegant appearance, these units stand as a testament to Hearth and Home Technologies' dedication to quality in the home heating market.