7 Electrical Information

A. Intellifire Ignition System Wiring

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack which is located in the ON/OFF switch terminal box. A wiring diagram is shown in Figure 7.1.

The battery pack requires two D cell batteries (not included). See Section 12.B. for battery replacement.

WARNING

Shock Risk

Replace damaged wire with type 105° C rated wire.

Wire must have high temperature insulation.

CAUTION

Battery polarity must be correct or module damage will occur.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

 

 

IGNITION MODULE

 

I

 

 

 

 

 

3 VAC

 

 

INTERMITTENT

 

 

 

 

 

 

S

PILOT

 

 

 

 

 

 

IGNITOR

 

 

 

 

 

 

 

 

 

BATTERY

 

 

 

 

 

 

 

PACK

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

 

WALL

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

FLAME SPARKER/

 

 

 

WHT

 

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

IGNITION

 

BATTERY

 

 

ORG

 

 

MODULE

 

 

 

 

 

 

(3V)

 

PACK

BLACK

 

GROUND TO

 

 

 

 

 

 

FIREPLACE

 

 

 

 

 

 

CHASSIS

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

VALVE

LOW VOLTAGE

 

BRN

BRN

 

 

 

 

SEE NOTE 1

 

ORG

 

 

 

 

 

GRN

 

 

 

 

PIGGYBACK

 

 

 

 

 

 

 

ON/OFF SWITCH

 

 

 

 

 

 

 

 

VALVE

 

Figure 7.1 Intellefire Pilot Ignition (IPI) Wiring Diagram

 

 

 

 