BC36C/BC36R INSTALLATION INSTRUCTIONS

2.Chase Top

Construct a chase of desired materials maintaining a minimum 2 in. air space around the chimney.

3.Termination Cap

a.Install the chimney sections up through the chase enclosure. When using a TR344 round termination cap, the uppermost top section of pipe must extend 6 in. above the top of the chase collar to allow installation of the storm collar and termination cap. See Figure 22.

b.For installations utilizing a TR342 telescoping round termination cap, the uppermost chimney section must be below the top of the chase top, but not more than 14-1/2 in. below the top of the chase top flashing collar. See Figure 23.

Figure 22 - Installing a TR344 Round Termination Cap

Figure 23 - Installing a TR342 Round

Telescoping Termination Cap

08/04

34962 Rev G