Hearth and Home Technologies DVP-FBHT Installation and use of any damaged vent system component

Models: DVP-FBHT

1 3
Download 3 pages 8.98 Kb
Page 2
Image 2
•Installation and use of any damaged vent system component.

•Modification of the vent system. WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged vent system component.

Modification of the vent system.

Installation other than as instructed by Hearth & Home Technologies.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

4.Install the telescoping flue section included with the cap on the last section of flue pipe.

•Installation other than as instructed by Hearth & Home Technologies. WARNING

Fire Hazard

Impaired performance of appliance

• Telescoping flue section of termination cap MUST be used when connecting pipe section to termination cap.

Maintain a 1-1/2 inch minimum overlap on telescoping flue section of termination cap.

5.Remove the three bolts from the firebrick cap face to separate the firebrick part of the cap from the metal backplate (see Figure 1).

6.Slide the backplate, with the 8 inch collar on it, onto the flue pipe from the fireplace. For thinner wall construction, you may have to trim the heat shield on the metal backplate and interior wall shield firestop.

Any such action may cause a fire hazard. WARNING

Fire Risk

Exhaust Fumes Risk

Impaired Performance of Appliance

• Overlap pipe slip sections at least 1-1/2 inches.

Use pilot holes for screws.

Screws must not exceed 1 inch long.

Pipe may separate if not properly joined.

NOTE: The heat shield on the interior wall shield firestop and the heat shield on the metal backplate must overlap 1-1/2 inches. If wall thickness does not allow the required 1-1/2 inch heat shield overlap, an extended heat shield must be used.

7.Secure the backplate to the wall with four appropriate length screws from the hardware pack.

8.Seal the backplate to the housewrap or sheathing. Follow housewrap manufacturer’s instructions for sealing a penetration when applicable.

9.Slide the firebrick part of the cap onto the backplate by aligning the 5 inch collar with the 5 inch flue pipe coming from the fireplace. Slide the two pieces together until the firebrick part bottoms out on the backplate.

10.Replace the three bolts removed in step 2. DO NOT OVERTIGHTEN THE BOLTS.

Measure vertical

 

clearances from

 

this surface.

 

 

Measure horizontal

 

clearances from

 

this surface.

1 in.

7-3/16 in.

(25)

(182)

 

14 in.

 

(356)

 

3/8 in. (9)

 

1 in. (25)

 

10-3/8 in. (264) Max.

 

7-11/16 in. (195) Min.

 

12 in.

 

(305)

Figure 2.

 

2

Page 2
Image 2
Hearth and Home Technologies DVP-FBHT Installation and use of any damaged vent system component, Fire Hazard