•The conversion kits for all “M” series log sets are:

These gas log sets are available with different valve systems. The Fi36S, Fi36SL, Fi42S and Fi42SL sets use a separate regulator and valve system, and the Fi36M, Fi36ML, Fi42M and Fi42ML sets use a combination control with an intermit- tent pilot. Both valve systems are available in natural or propane gas. Only the “M” Series can be used with an optional remote control (RC-BATT-HTL).

Conversion kits to convert from natural gas to propane or from propane to natural gas are available.

The conversion kits for all “M” series log sets are:

-DCKP to convert from natural gas to propane

-DCKN to convert from propane to natural gas.

The conversion kits for all “S” series log sets are:

-CKMP to convert from natural to propane gas

-CKMN to convert from propane to natural gas.

These HEATILATOR® gas log sets and components have been tested and will operate safely when installed in accor- dance with this installation manual. This decorative appliance is a highly engineered system. Unless you use HEATILA- TOR® components which have been designed for the system, you may create a fire hazard.

 

Model No.

BTU/Hr. Input

 

Orifice

 

 

Fi36M

 

 

 

 

.152

 

 

 

 

 

 

 

 

 

 

Fi36ML

 

60,000

 

.093

 

 

Fi36S

 

 

.169

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fi36SL

 

 

 

 

.093

 

 

 

 

 

 

 

 

 

 

Fi42M

 

 

 

 

.182

 

 

Fi42ML

 

80,000

 

.110

 

 

 

 

 

 

 

 

Fi42S

 

 

.228

 

 

 

 

 

 

 

 

Fi42SL

 

 

 

 

.110

 

 

 

 

 

 

 

 

 

Gas Pressure

 

 

Inlet gas supply pressure (NG)

 

4.5 (min) - 7.0 (max) in. w.c.

Optimal manifold pressure (NG)

3.5 in. w.c.

 

 

Inlet gas supply pressure (LP)

 

11.0 (min) - 14.0 (max) in. w.c.

 

 

 

 

Optimum manifold pressure (LP)

10 in. w.c.

 

 