A. Maintenance Tasks

Inspect

 

Maintenance Tasks

Doors

1.

Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to air flow.

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.

 

3.

Confirm there is no damage to glass or glass frame, Replace as necessary.

 

4.

Verify that latches engage properly and glass attachment components are intact and operat-

 

ing properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be

 

removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as neces-

 

sary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as neces-

 

sary.

 

2.

Replace appliance if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary. USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.

 

3.

Replace ember material with new dime-size and shape pieces. Do not block ports or obstruct

 

lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting and other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple/thermopile sensor rod for soot, corrosion and deterioration. Clean with

 

emery cloth or replace as required.

 

10. Verify millivolt output. Replace as necessary.

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote Controls

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

September 1, 2008

Quadra-Fire · Garnet-T · 7016-127F

Page 43

Page 43
Image 43
Hearth and Home Technologies GARNET-D-MBK, GARNET-D-CSB, GARNET-MBK, GARNET-D-CWL, GARNET-D-PMH Maintenance Tasks Inspect

GARNET-D-CSB, GARNET-D-CWL, GARNET-MBK, GARNET-D-PMH, GARNET-D-MBK specifications

Hearth and Home Technologies has a reputation for excellence in the home heating and comfort industry, offering a range of top-tier products that combine modern design with functionality. Among their esteemed offerings are the GARNET-D-MBK, GARNET-D-PMH, GARNET-MBK, GARNET-D-CWL, and GARNET-D-CSB units, each designed to meet diverse consumer preferences while promoting efficiency and style.

The GARNET-D-MBK model, characterized by its sleek black finish, seamlessly integrates into contemporary living spaces. It boasts an efficient heating system that utilizes advanced combustion technology to maximize heat output while minimizing emissions. Its easy-to-use interface ensures users can control the device with minimal effort, making it ideal for both seasoned and first-time stove owners.

In contrast, the GARNET-D-PMH features a polished mahogany finish that appeals to those wanting a classic aesthetic. This model incorporates cutting-edge burn technology, which not only enhances heat retention but also significantly reduces the time required to achieve optimal temperatures. With its thoughtful design and craftsmanship, the GARNET-D-PMH stands as a beautiful centerpiece in any room.

Moving on to the GARNET-MBK, this model offers the same high efficiency as its counterparts with an added advantage of a modular design. This adaptability allows homeowners to customize the unit based on their specific space requirements. Its multiple heating settings cater well to varying temperatures, contributing to its reputation as an energy-efficient alternative.

The GARNET-D-CWL model is distinguished by its compact design and rugged construction. This product was engineered for utility while maintaining aesthetic appeal. The unit’s innovative technology not only ensures impressive heat output but also incorporates safety features that make it a reliable choice for families.

Lastly, the GARNET-D-CSB encapsulates the essence of versatility. This model effortlessly balances function and design, featuring an elegant coating that enhances durability. Its digital controls offer precision in temperature management, while its efficient energy use aligns with modern environmental standards.

Across all these models, Hearth and Home Technologies prioritizes quality, utilizing durable materials and state-of-the-art engineering techniques. Their commitment to customer satisfaction and environmental responsibility is evident in every unit, making these garnet series products standout choices for effective home heating solutions.