Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. F • 11/08 53Figure 12.2 Intelli re Ignition Wiring Diagram with Wall Switch or ThermostatFigure 12.3 Intelli re Ignition Wiring Diagram with Remote ReceiverNOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.
TRANSFORMER
3 VAC
PLUG IN
BLACK
RED
BATTERY PACK
THERMOSTAT
WIRE ASSEMBLY
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
HOT
NEUTRAL
GROUND TO
FIREPLACE
CHASSIS
WHITE
ORANGE
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
I
S
TRANSFORMER
3 VAC
PLUG IN
PLUG IN

BLACK

RED

BATTERY PACK
REMOTE
WIRES
(TO BROWN)
ORANGE
GREEN
VALVE
GROUND TO
FIREPLACE
CHASSIS
HOT
NEUTRAL
WHITE
ORANGE
IGNITION
MODULE 3 VAC
INTERMITTENT
PILOT IGNITOR
I
S