•SIT Valve

Dexen Valve (IPI)

-Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction box as shown in Figure 10.

-Connect the black ground wire to the appliance.

-Remove the green ignition control wire from the valve.

-Connect the black with white stripe wire with 3/16 in. piggyback connector from fan control module to valve.

-Connect green ignition control wire to piggyback connector on black with white stripe fan control module wire.

Dexen

Wire from Ignition Control

 

Green

 

Valve

 

Black/White

 

 

White

Fan

 

Black

 

Control

Red

 

Module

 

 

Ground

 

Black

 

 

Figure 10 - Dexen (IPI) Wiring Diagram

 

SIT Valve

-Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction box as shown in Figure 11.

-Connect the black ground wire with the ring terminal to the TP screw on the valve (center).

-Connect blue jumper wire between fan control wire (black with white stripe) and valve. Plug 1/4 in. female end of blue jumper wire to the back side of valve wiring block marked TH.

Thermopile

Wall

Switch

SIT

TH

TP

Valve

TH TP

 

Ground

Black/White

 

Black

 

White

Red

Blue

 

Fan

Control

Module

White

Red

Black

Figure 11 - SIT Wiring Diagram

6. Recommended Fan Control Set-up Procedure

Note: The test sequence works only during the first (approximately) seven minutes after power-up.

With burner and pilot extinguished:

Turn control knob clockwise to activate control.

Press and hold test button on the control module.

-Fan will turn on.

-Adjust fan speed with control knob.

-Release test button. Fan will stop.

Light burner.

Press and release test button.

-Fan will come on at set speed

-After one minute fan will stop.

Extinguish burner.

Fan control is now fully operational and will operate automatically each time appliance is used.

Operates with APPROXIMATELY a 7-minute delay to turn on and a 12-minute delay to turn off.