2. Remove Valve Assembly
On a Novus 30 in. appliance (GNDC30 or GNBC30 only) the valve assembly must be raised slightly to allow the fan to be moved past it to the back of the appliance.
3. Install the Fan
Position the fan all the way to the rear and center in the ap- pliance. Press the fan (magnets to the bottom) to the back of the appliance. See Figure 7. Plug the fan cord into the fan receptacle labeled “FAN” on the junction box. See Figure 8.
4. Install the Control Module
Attach the control module to the bottom pan using the mag- netic tape provided.
5. Wiring the Fan Control Module
Note: Fan control timer only for use on units with junction box pictured in Figure 9.
•Robertshaw Valve (Standing Pilot)
-Connect the black, white and red wires with 1/4 in. female connectors from the fan control module to the appliance junction box as shown in Figure 9.
-Connect the black ground wire with the ring terminal to the TP screw on the valve (center).
-Remove wall switch wire connected to valve terminal marked “TH”.
-Connect the black with white stripe wire with 3/16 in. piggyback connector from fan control module to valve terminal marked “TH”.
-Connect wall switch wire removed from valve terminal “TH” to the piggyback connector on the black with white stripe fan control module wire.
Note: Thermopile must be wired as shown in Figure 9.
FIREBOX |
| |
BOTTOM |
| |
| FAN | APPLIANCE |
|
| |
|
| BACK |
BOTTOM PAN |
| |
Figure 7 | Rotate Fan |
|
Fan Assembly
Cord
Clips
Junction Box
Figure 8 Position the Fan
|
|
|
| Thermopile | Wall |
|
|
|
|
|
| Switch |
|
|
|
| TH | White |
|
|
| RS |
|
|
|
| |
|
| TP |
|
|
| |
| Valve |
| Red |
|
| |
|
| TH TP |
|
| ||
|
|
|
|
|
| |
| Black Ground | Black/White |
|
| White |
|
|
| Fan |
|
| ||
|
| Control | Red |
| ||
|
|
|
|
| ||
|
|
|
| Module |
| |
|
|
|
|
|
| |
|
|
|
|
| Black |
|
Figure 9 | Robertshaw Wiring Diagram |
|
| |||
|