B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specified in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials.

Storm Collar

Roof Flashing

(attic)

(insulation)

2 in. (51 mm) min.

Shaded areas

represent

2 in. (51 mm) min. air space clearance required around pipe

Attic

Insulation

Shield

(ceiling)

Offset/Return (secured

with hanger straps)

(ceiling)

Ceiling Firestop

Object

 

 

 

 

 

48 in.

 

Combustible

 

1219 mm

 

 

 

0 in.

 

 

 

 

 

 

to floor

 

 

 

 

Must have 2 in. (51 mm)

minimum clearance

to header

0 in. to level of standoffs

1/2 in. (13 mm) to back & sides of appliance

Figure 6.2 Clearances to Combustible Materials

Note: Chimney air kit is not shown, but is required in Canada.

Heat & Glo • HST-42D • 27177 • Rev AB • 11/08

19

Page 19
Image 19
Hearth and Home Technologies HST-42D owner manual Clearances to Combustible Materials