For Vertical Terminations - To locate the vent and install the vent sections:

• Locate and mark the vent centerpoint on the underside

of the roof, and drive a nail through the centerpoint.

• Make the outline of the roof hole around the centerpoint

nail.

• The size of the roof hole framing dimensions depend on the

pitch of the roof. There MUST BE a 1-inch (25.4mm) clear-

ance from the vertical vent pipe to combustible materials.

• Mark the roof hole accordingly.

To seal the roof hole, and to divert rain and snow from the vent system:

Attach a flashing to the roof using nails, and use a non- hardening mastic around the edges of the flashing base where it meets the roof.

Attach a storm collar over the flashing joint to form a water-tight seal. Place non-hardening mastic around the joint, between the storm collar and the vertical pipe.

Slide the termination cap over the end of the vent pipe and rotate the pipe clockwise 1/4 turn.

• Cover the opening of the installed vent pipes.

• Cut and frame the roof hole.

• Use framing lumber the same size as the roof rafters

and install the frame securely. Flashing anchored to the

frame must withstand heavy winds.

• Continue to install concentric vent sections up through

the roof hole (for inside vent installations) or up past the

roof line until you reach the appropriate distance above

the roof (for outside terminations).

2 FT.

2 FT. MIN.

MIN.

 

 

LOWEST

 

DISCHARGE

TERMINATION

OPENING

 

CAP

 

HORIZONTAL

OVERHANG

VERTICAL

WALL

X

12

!WARNING: MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR

VENT HEIGHT ABOVE THE ROOF TOP. THESE MIN- IMUM HEIGHTS ARE NECESSARY IN THE INTER- EST OF SAFETY. SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS, PROVIDED THE TERMI- NATION CAP IS AT LEAST TWO (2) FEET FROM A VERTICAL WALL AND 2-FEET BELOW A HORIZON- TAL OVERHANG.

NOTE: This also pertains to vertical vent systems in- stalled on the outside of the building.

ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF

TO LOWEST DISCHARGE OPENING

Roof Pitch

H (min.) ft.

flat to 6/12

1.0

6/12 to 7/12

1.25

over 7/12 to 8/12

1.5

over 8/12 to 9/12

2.0

over 9/12 to 10/12

2.5

over 10/12 to 11/12

3.25

over 11/12 to 12/12

4.0

over 12/12 to 14/12

5.0

over 14/12 to 16/12

6.0

over 16/12 to 18/12

7.0

over 18/12 to 20/12

7.5

over 20/12 to 21/12

8.0

Figure 28. Minimum Height from Roof to Lowest Discharge Opening

32

Page 32
Image 32
Hearth and Home Technologies R-CORNER-TRC, PIER-TRC, L-CORNER-TRC manual Minimum Height from Roof to Lowest Discharge Opening

L-CORNER-TRC, R-CORNER-TRC, ST-TRC, PIER-TRC specifications

Hearth and Home Technologies offers an impressive range of fireplace products that blend aesthetics with advanced technology. Among their innovative lineup, the PIER-TRC, ST-TRC, R-CORNER-TRC, and L-CORNER-TRC models stand out as versatile and stylish options for modern homes. Each of these fireplace units is designed to enhance the ambiance of a space while providing reliable performance.

The PIER-TRC model is ideal for those seeking a focal point in a living room or gathering space. This pier-style fireplace is characterized by its striking, contemporary design and clean lines. It allows for a three-sided view of the flames, creating a captivating visual experience from various angles. The PIER-TRC incorporates advanced venting technology, ensuring efficient heat distribution without compromising on aesthetics. Homeowners can choose from a selection of decorative media options to personalize the appearance, adding a unique touch to any interior.

Next, the ST-TRC model is a sleek, modern fireplace that excels in providing both form and function. Its space-saving design makes it a perfect choice for smaller rooms while still delivering ample heat output. The ST-TRC features a linear, minimalist look that fits seamlessly with contemporary decor. Advanced electronic ignition systems enable effortless operation, while the option for smart home integration allows users to control the fireplace with ease using mobile devices.

For those looking to create a cozy corner in their living space, both the R-CORNER-TRC and L-CORNER-TRC models offer an excellent solution. Designed specifically for corner placements, these fireplaces feature a unique design that allows for a two-sided viewing experience. The R-CORNER-TRC wraps around the right side, while the L-CORNER-TRC offers a similar aesthetic for the left. Both models utilize cutting-edge technology to ensure efficient heating and combustion, with adjustable flame settings that let users customize their experience.

All of these models come equipped with high-efficiency burners, maximizing heat output while minimizing fuel consumption. Hearth and Home Technologies ensure that each unit meets stringent safety and performance standards. With a commitment to quality and innovation, they provide homeowners with stylish and functional solutions that enhance the warmth and comfort of their living spaces.

In conclusion, the PIER-TRC, ST-TRC, R-CORNER-TRC, and L-CORNER-TRC fireplaces from Hearth and Home Technologies provide a perfect balance of elegance, efficiency, and versatility. Each model showcases advanced technologies and design features that cater to modern needs, making them an excellent choice for any home.